MTF 1500/250 MTF 750/160editionedition

The MAPLAN machine series edition, in vertical – full hydraulic design with the original MAPLAN FIFO rubber injection unit represents the optimum of productive efficiency and compactness in production of rubber- and rubber-combination parts.

 

tr

Machine equipment


Standard equipment: Options:


• Microprocessor-control PC5000touch

• Electronic positioning system for clamp- and

injection unit, ejector injection and clamp side

• Energy saving hydraulic pump with proportional

pressure / flow control

• 2-circuit-cooling unit (thermo oil) for plasticizing cylinder

and injection pot

• Light shield



• Hydraulic ejector injection and/or clamp side

• Heating and cooling devices for plasticizing cylinder,

injection pot, screw or cold runners

• Vacuum pump

• Oil filter, Oil level- and oil temperature control

• Microprocessor control features for PC5000touch

• Alternative injection volume 2000cm³

• Additional mould heating zones

• Strip intake control

• Automatic strip intake device

• Hydraulic sliding plates 70%

• Electric backpressure adjustment

• 3-zone heating plates control

• 5l-Stockfeeder for silicone processing

• Euromap67 interface

• PAC - driving from up to 4 free programmable

additional movements

• Oil cooling



tr

Technical data/Dimensions:


MTF 1500/250 Heizplattte

MTF 1500/250 Draufsicht

Clamping unit
Injection units
1500
2000
Opening stroke mm 500 Max. injection volume cm³ 1500 2000
Opening between plates mm 700 Max. injection pressure bar 1980 1500
Clamping force kN 2500 Max. injection capacity cm³/sec 74 99
Opening force kN 74,6 Screw diameter mm 42 42
Clamping speed mm/sec 365 Screw ratio L/D 9 D 9 D
Opening speed mm/sec 169 Max. Screw speed rpm 135 135
Min. mould height mm 200 Plasticizing capacity cm³/min 940 940
Electric equipment
Hydraulic unit
Motor rating kW 7,5 System pressure bar 220
Heating plates kW 14 Pump output l/min 42
Control voltage V 24 V=
Connected load° kW 25 Machine weight kg 9000
Temperature zones total   5 Floor space required 3,6

° without additional heating and cooling/heating devices

values for 50Hz, subject to technical modifications

For further Information please complete the contact form.