MTF 2500/400 MTF 2500/400editionedition

The MAPLAN machine series edition, in vertical – full hydraulic design with the original MAPLAN FIFO rubber injection unit represents the optimum of productive efficiency and compactness in production of rubber- and rubber-combination parts.

 

 



 

 

tr

Machine equipment


Standard equipment: Options:


• Microprocessor-control PC5000touch

• Electronic positioning system for clamp- and

injection unit, ejector injection and clamp side

• Energy saving hydraulic pump with proportional

pressure / flow control

• 2-circuit-cooling unit (thermo oil) for plasticizing cylinder

and injection pot

• Light shield



• Hydraulic ejector injection and/or clamp side

• Heating and cooling devices for plasticizing cylinder,

injection pot, screw or cold runners

• Vacuum pump

• Oil filter, Oil level- and oil temperature control

• Microprocessor control features for PC5000touch

• Alternative injection volume 3200cm³

• Additional mould heating zones

• Strip intake control

• Automatic strip intake device

• Hydraulic sliding plates 70%

• Electric backpressure adjustment

• 3-zone heating plates control

• 15l-Stockfeeder for silicone processing

• Euromap67 interface

• PAC - driving from up to 4 free programmable

additional movements

• Oil cooling



tr

Technical data/Dimensions:


MTF 2500/400 Heizplatte

MTF 1500/250 Draufsicht

Clamping unit
Injection units
2500
3200
Opening stroke mm 580 Max. injection volume cm³ 2500 3200
Opening between plates mm 830 Max. injection pressure bar 1917 1500
Clamping force kN 4120 Max. injection capacity cm³/sec 120 155
Opening force kN 128,7 Screw diameter mm 52 52
Clamping speed mm/sec 250 Screw ratio L/D 9 D 9 D
Opening speed mm/sec 160 Max. Screw speed rpm 105 105
Min. mould height mm 250 Plasticizing capacity cm³/min 1050 1050
Electric equipment
Hydraulic unit
Motor rating kW 22 System pressure bar 210
Heating plates kW 25,8 Pump output l/min 65
Control voltage V 24 V=
Connected load° kW 55 Machine weight kg 14200
Temperature zones total   5 Floor space required 4,2

° without additional heating and cooling/heating devices

values for 50Hz, subject to technical modifications

For further Information please complete the contact form.